Fixed a bunch of typos and issues in syscontrol uevent update
This commit is contained in:
parent
f8f500d306
commit
2031ca424e
|
@ -90,19 +90,19 @@ syscontrol.power_supply.read_attribs = function(dev_name)
|
|||
end
|
||||
local uevent_data = {}
|
||||
local device = {
|
||||
type = fhandler:read("*a"),
|
||||
type = fhandler:read("*a"):match("%S*"),
|
||||
full_path = "/sys/class/power_supply/"..dev_name,
|
||||
name = dev_name
|
||||
}
|
||||
fhandler:close()
|
||||
uevent:read("*a"):gsub("[^\n]+",function(line)
|
||||
uevent_f:read("*a"):gsub("[^\n]+",function(line)
|
||||
local key,value = line:match("^([^=]+)=([^=]*)")
|
||||
if value:match("^%d+$") then
|
||||
value = tonumber(value)
|
||||
end
|
||||
uevent_data[key] = value
|
||||
end)
|
||||
uevent:close()
|
||||
uevent_f:close()
|
||||
if device.type == "Battery" then
|
||||
device.model = uevent_data.POWER_SUPPLY_MODEL_NAME or "N/A"
|
||||
device.energy_full_design = uevent_data.POWER_SUPPLY_ENERGY_FULL_DESIGN
|
||||
|
@ -117,6 +117,7 @@ syscontrol.power_supply.read_attribs = function(dev_name)
|
|||
elseif device.type == "Mains" then
|
||||
device.online = (uevent_data.POWER_SUPPLY_ONLINE == 1)
|
||||
end
|
||||
return device
|
||||
else
|
||||
return nil, err
|
||||
end
|
||||
|
|
Loading…